Check connection. BigCommerce Premium Themes by PSDCenter. It uses 240V and 50/60hz Export. The cartridge must be replaced. Look for heavy corrosion at both ends. This product hasn't received any reviews yet. This may be necessary after heavy rains, backwashing and refilling, excessive splash out, etc. Add salt as described in Section 4.7 of the owner's manual. I have upgraded the circuits boards as per Zodiac's support advice and they only made the problem less prevalent. If the salinity is above 4.0 gpl, the unit will cut off and give error code 145 (High Salinity). While still pressing the test buttons press the Salinity key (C) on the front cover of the unit. Free Shipping and more for Pool Perks members. The problem is that the O-rings can leak, which creates a corrosive mix of water, salt, hydrogen gas and chlorine gas. Control CenterThe control center converts AC electrical current to a low voltage DC current which is required by the cell to perform the electrolysis. If the chlorinator is the correct size, then it's sufficient to sanitize the pool without adding granular chlorine. Decrease the chlorine production rate adjustment button (arrow button A). inground with iAqualink remote control. Please try again. Will there be any harm if someone swallows salt water in a salt chlorinated pool? The salt under the effect of electrolysis, is transformed into sodium hypochlorite, a disinfectant. Add stabilizer to maintain 50 - 75 PPM per pool professionals recommendations. Please make sure that you are posting in the form of a question. As for information, the internet is a great thing. The Jandy AquaPure system consists of a AquaPure Power Center or PureLink Power Centers and either a PURE700 cell or a PURE1400 cell. Does the Freeze Protect mode use the reading from the tri-sensor or the pool temperature sensor? Ensure that the flow/temp/salinity sensor is installed according to Section 3, Figure 11 of the owner's manual. Refer to Maintenance Procedure for acid wash cleaning. Includes: 1 - Power Interface Board Assembly. Rely on its sturdy design and simple features to create your saltwater oasis. Recommend strongly. See Section 6.3 of the owner's manual, Electrolytic Cell Cleaning. Works like a champ. Power Center Compatible with Pentair IntelliChlor Pool, APPLIAFIT O-Ring Compatible with Jandy Zodiac R0357800 for CL, CV, DEL & DEV Series Filters (2-Pack), Tier1 Pool & Spa Filter Cartridge | Replacement for Dimension One 1561-00, Pleatco PDO75-2000, FC-3059, C-7367, Aladdin 17541 and More | 75 sq ft Pleated Fabric Filter Media, POOLPURE PDM28 Spa Filter Replaces Aquarest Dream Maker 461273 Hot Tub Filter, 2 Pack, SpaO2 Swimming Pool Aerators - Set of 2, ABS Injection Molding, Fit 1-1/2 FIP/MIP Threaded Return outlets, MAX Depth 19.7, Raise pH Without Changing Alkalinity, Crystal Clear Water, Less Chemicals, 1996-2023, Amazon.com, Inc. or its affiliates, Zodiac APUREM AquaPure Foundation Power Center Pack Replacement for Zodiac Jandy AquaPure PureLink Cell Kit. Also look inside the cell at the cord end. Below 51F (11C), chlorine production is not permitted; operating the chlorinator in cold water might result in over-chlorinated pool water. Would recommend it to anyone needing a replacement or installinf for the first time. Remove cell for inspection. This can usually be prevented by sealing the stone with a sealer. Dont use the little adaptor card between the cord plug and the circuit board. The Flow & Salinity Sensor is Jandy P/N R0452500. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. 2 - Screws, Power Interface. The arrow points to the water temperature sensor. While still holding the two front board test buttons press the Pool Temperature key (D). In this thread, the amperage of the 1400 cell tests at about 5.6 amps, and the amperage of the 700 cell should test at about 2.8 amps.[11]. Easy to install and use. Avoid using salt with anti-caking agents (sodium ferrocyanide, also known as YPS or yellow prussiate of soda) that could cause some discoloration of fittings and surface finishes in pool. Water conditioning salt pellets take longer to dissolve. We are sorry. A separate communication will follow . From the Jandy controller, you can see the salt PPM, and you get a menu for setting the production rate percent for pool and spa modes - perfect. If still too low, Super Chlorinate with outside source. There were instructions included, but they were not as comprehensive as you would really need. Do I still need to use granular chlorine with my Salt water chlorinator? Less work = longer life. 20 points earns $1 Pool Perks reward. Had to call a pool guy. It looks like WhatsApp is not installed on your phone. If burnt connector contact authorized service representative. 2023 Zodiac Pool Systems LLC - All rights reserved. Jandy Aquapure Clormatic III Front Panel Control Board Psd306-01 Apure1400 . Adjust total alkalinity to 80-120ppm. Please consider. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. It should use the Air temperature sensor. Natural stone liners or ornaments may be more susceptible to blemishes and erosion when using pool water treatments. Older Power Centers use a rectangle transformer P/N T1005 that is no longer available. Most common is the center pin.[9]. In addition, the AquaPure threads are proprietary and Jandy does not offer replacement proprietary unions (the "male" piece). Leslie's Pool Supplies does not share or sell personal info. This Jandy Power Center Transformer is compatible for use with the AquaLink RS and AquaPure automatic control systems. While the salt water chlorinator prevents the user from needing to add chlorine to the pool on a regular basis, some maintenance, in regards to water balancing, will still need to be accomplished. Water conditioning salt pellets are compressed forms of evaporated salt and may be used. Pricing and offers are subject to change. Please try again later. FREE delivery Feb 16 . IS this the complete system? It should read 75 F or 24 C. Next, press and hold the board H-Temp test button, and at the same time press the Salinity key (C) together with the Chlorine Production Rate arrow down key (A) on the front cover of the unit. It displays the salt level in PPM on the display, and you can set the production rate (0-100%) on the LCD display, or you can integrate the system with a Jandy controller as I did. The 700 cell has half the number of plates as the 1400 cell. It's cheaper to go with another salt unit if you are replacing the old Jandy unit, as was my case. Wichita Falls, TX. Register product at Jandy.com/registration. This aquapure is use with PLC700 or PLc1400 for salt system only. FREE delivery Feb 16 - 21 . No Flow indicator stays on continuously. When I check the water temperature on my Aqualink Control Center by quickly pressing the Pool Temp Boost button, it shows 85 degrees which I believe is correct. Consult your pool professional regarding use of a sequestering agent. Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115/230VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. The AquaPure system offers two cells that can generate different maximum amounts of chlorine in a 24 hour period. There was a problem adding this item to Cart. They can tell which ones are bad by the serial number. Add salt to pool, 3.0 gpl to 3.5 gpl. (Cycle Power). With the AquaPure 1400, the reading is in grams per liter, which is the same as 1,000 ppm. The AquaPure control center converts AC power into low voltage DC current which is required by the cell to perform the electrolysis. Press and hold the test buttons marked salinity and R-temp. So it looks like it is good, but the water temp sensor is bad. Please note: This item is only available for in-store pickup and the selected store is out of stock. Andy tech support makes jokes that I should get it fixed before my pool turns green and yet have not been able to fix the problems nor willing to try. Jandy Zodiac AquaPure PLC1400 PLC 1400 Saltwater Cell Kit AQUA PURE. The audible alarm is described on page 34 of the Jandy Pro Series AquaPure/PureLink Power Center and Cell Kit | Installation and Operation Manual.[4]. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. You need the Aquapure system with the control box and cell. You use the% generation control to adjust the actual amount of chlorine generated to meet your pools chlorine need. It may not display this or other websites correctly. Had to down load from another site. Brand new! Aqualink prevents the Aquapure system from proper operation without a functioning water temperature signal from the Aqualink stand alone water temperature sensor, regardless of what the SWG flow sensor says. Add To Cart. 2023 Leslies Poolmart Inc. Were sorry we missed you; we look forward to assisting you soon. veggiebenz; Aug 8, 2022; Salt Water Chlorine Generators (SWG) Replies 2 . Would buy again from them. The system then reuses the salt and the process starts over again. You are dealing with 240 Volts and electrical circuits. All other firmware uses program B on the trisensor inline module. The only hiccup we get, is an occasional communication error. If the readings are correct then the board is O.K. Only 17 left in stock - order soon. Use Up and Down arrow keys to navigate search results. I bought one of these units from another vendor three years ago. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. No warranty when purchased online. Jandy AquaPure control center for Jandy AquaPure PLC1400 and PLC700 chlorine generator cells. When I check the water temperature on my Aqualink Control Center by quickly pressing the Pool Temp Boost button, it shows 85 degrees which I believe is correct. Hypochlorite kills bacteria, oxidizes organic material, and kills algae then reverts back to salt. The system will beep when you push it and then at 5 seconds and again at 10 seconds. If the ladder is bonded properly to the rest of the pool equipment, corrosion will be minimal. Remove cell for inspection. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. Check the water balance as usual. Natural stone can be visually altered over time. The only difference is the new part has a ground wire that was attached to the common ground.[15]. An optional "Spool" Piece (sold separately) used to be available to replace the cell during winterizing or cell maintenance. The AquaPure does not have a flow switch, it has a flow sensor, which is a heated probe and and unheated probe and it works on the same principle as "wind chill".[1]. First thing to check is the cord. If so, why the 2 different readings? The AquaPure cells can be controlled by the AquaPure user interface inside the control/power center or by the Aqualink automation systems. Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115 / 230 VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. Then adjust pH to within the range 7.4-7.6. It is possible his sensors are reversed. Pool and Spa Parts Depot | Swimming Pool Supplies. ), PURE1400 - 1.25 lb./24 Hr. The AquaPure has a 3 hour polarity cycle time (3 hours one polarity, 3 hours reverse polarity). See Section 6.3 of the owner's manual Electrolytic Cell Cleaning. Zodiac Brand Item Number R0467600. $1,079.00. After 24 hours, verify correct salt reading. . If the unit does not read 2.8 gpl for salinity, then the unit has been recalibrated. Backwash or partially drain pool and dilute with fresh water until salinity returns to 3.0 gpl to 3.5 gpl. Scale formation on pool equipment. Check that ribbon cable is fully inserted into connector. PLC700 (Cell Kit)
A common reason for the cell failing and getting error codes 120, 121 or 123 is one or more of the pins corroding and separating from its plate. This difference in readings started about 1 week ago. We will contact you as soon as this product is available. Check for correct operation of the pump. That can be from low salt, low water temperature, a bad power cord, cell plates corroded or loose power pins. Sorry, we were unable to perform your search at this time. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. The Jandy AquaPure salt-water chlorine purifying systems use salt water to deliver high-performance water purification with uncompromised performance, reliability and hydraulic efficiency. However, when I power on the AquaLink PDA, it shows the water temp is 120 degrees. Otherwise the back circuit board may need replacement. Rather than swapping my existing power center for 6613-AP (no breakers), I prefer to add an APUREM subpanel power center and run the four-wire harness over to the iAquaLink board. You are using an out of date browser. See Section 6 of the owner's manual, User Maintenance Instructions. No instructions contained w/unit. If there is still a large amount of bromide in your pool, we recommend that you wait for it to dissipate. The mineral purifier cartridge may have ruptured. This warranty applies only to products installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed, where such state or local requirements exists. 1 - Face Plate, Control Center, APUREM. (Take pool water sample to Pool Professional). Plug flow/temp/salinity sensor into connector on power center printed circuit board. Measures 6-inch diameter by 14-inch width by 9-1/2-inch height. Use a salt that is at least 99.8% pure NaCl. The air temp went up. This Jandy Power Center Transformer is compatible for use with the AquaLink RS and AquaPure automatic control systems. How does Aqualink RS Manage Solar and Gas Heating, Jandy IAqualink WiFi module with PDA Remote, iAqualink freeze protection - two specific questions, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. The manual says that the unit can be damaged, which could void the warranty. >PoolAndSpaPartsDepot.com is Open for Business! Help others learn more about this product by uploading a video! Apple is not a participant or sponsor of this promotion. Your question might be answered by sellers, manufacturers, or customers who bought this product. Balance the water to recommended levels in Section 4.5 of the owner's manual. Get 1 point for every $1 spent. These clowns should join the Not reliable at all and have had problems starting about 1 month after installation. Sorry - Air temperature sensor. You can remove your cell for winter and install the dummy cell. Winterize your pool. The aquapure power center is an electrical panel that is installed at the equipment pad. Looks like your current store isn't near your delivery area. It is being practiced by thousands of pool owners just like you. It displays the salt level in PPM on the display, and you can set the production rate (0-100%) on the LCD display, or you can integrate the system with a Jandy controller as I did. Check Cell studs for same. 120 is low current. The TRI sensor only pertains to the swg. To be more specific, do you mean the control board for the salt cell? Salt only needs to be added when necessary. Click the button below to add the JANDY AQUAPURE | CONTROL BOX, PURE1400 | R0403000 to your wish list. Jandy - Power Center Transformer for AquaLink RS and AquaPure. If you are switching from the 700 cell to the 1400 cell the JL1 jumper needs to be reconnected. This page was last edited on 21 November 2022, at 19:29. Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. The LCD display on the user interface offers monitoring of chlorine production, cell modes, salinity level, temperature, water flow and diagnostics. Boost 24 Hour 100% Chlorine Production Cycle. I'm upgrading my old AquaLink RS board to iAquaLink (with the IQ20-RS kit) and want to add an AquaPure 1400 salt generator. In fairness to Zodiac/Jandy, they feel that a pool professional should do this. See Section 6.5 of the owner's manual, Winterizing. The AquaPure system is comprised of the following three component parts and an optional pool pump timer. You know what? Remove and clean flow/temp/salinity sensor contacts. 21. Had to replace our original, 14 year old system which developed a front board issue. You can check the amperage to verify if the cell is generating. Is it true that a salt water chlorinator provides chlorine-free water? We could have gotten by with the PLC700 but this We made the decision to go to a salt water pool system. You need to determine the correct Revisio, Q: Sitemap | Set Boost mode and allow to run for 24 hours. You will get much more visibility by. Brush the pool bottom and allow water to circulate for 24 hours to dissolve salt completely and mix evenly Disconnect the flow salinity temp sensor from the front board. If more chlorine is needed, activating the Boost mode will override this cold water feature allowing chlorine production for 24 hours of operation. Low salt concentration below 2.0 gpl will cause premature cell failure. Available in 7 or 14-blade configurations. ORP / External Control Interface 2. You can usually see evidence of a leak when you know to look for it. Earn at least $9 in pool perks for this item by joining Pool Perks. Thanks, Problem solved. PLASTIC CONTROL CENTER, MODELS 700 & 1400, PARTS - BIG DIPPER, ECLIPSE, TOTAL ECLIPSE, COMPLETE HIGHCAPACITY BROMINE & CHLORINE FEEDERS, KREEPY E-Z VAC & KREEPY KADET ACCESSORIES, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, AMERICAN PRODUCTS 5 & 8 POSITION TOP MOUNT, SPA DRAIN & ON/OFF VALVES FOR GARDEN HOSE, STANDARD HEATER UNION COMPONENTS - 1", 200 SERIES TYPHOON JETS - SCALLOPED, 2" FACE, 300 SERIES TYPHOON JETS - SCALLOPED, 3" FACE, 400 SERIES TYPHOON JETS - SCALLOPED, 4" FACE, 500 SERIES TYPHOON JETS - SCALLOPED, 5" FACE, RETRO FITTING LEN GORDON & OTHER CONTROLS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, 200 SERIES TYPHOON JETS - SCALLOPED, 4" FACE, JANDY AQUAPURE | CONTROL BOX, PURE700 | R0402900, JANDY AQUAPURE | UNION NUT, 2" BLACK | R0412500, JANDY AQUAPURE | SALINITY METER | R0475300, JANDY AQUAPURE Ei | TS CONTROL PCB ASSY | R0512300, JANDY AQUAPURE | SPOOL PIECE, 2" BLACK UNIONS W/2803-009 | R0412800, POLARIS OZONATORS | 110/220V FOR UP TO 40,000 GALLONS | PZVII-2 | Discontinued, PENTAIR | HC-3330 HOUSING W/ 2098-0 | R172437, Pool and Spa Parts Depot | Swimming Pool Supplies.